›› 2011, Vol. 24 ›› Issue (12): 78-.
• Articles • Previous Articles Next Articles
HE Jing, WANG Yong-Sheng
Online:
Published:
Abstract:
In view of the difficulty of heat fee collection and unreasonable billing by area,a new type of intelligent meter and its accompanying remote automatic meter reading system is designed in this paper.The entire system is composed of warm air measuring appliance,data transmission system and PC.Through real-time measurement of voltage difference of Pt1000 bridge ends by the heat meter,it calculates the temperature by counting the Hall flowing meter.It obtains the flow value of the users in a short period of time by virtue of the final application of flow and heat.The amount of heat value measurement data can be passed through the CAN bus to the PC,whose management system processes the data.Testing shows that this scheme can achieve intelligent measurement of heat fee in communities.
Key words: billing heat;Pt1000;Hall flow meter
CLC Number:
HE Jing, WANG Yong-Sheng. The Temperature and Flow Sensor Design of the Research and Implementation of the Charge System of Heating for Separate Door[J]., 2011, 24(12): 78-.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://journal.xidian.edu.cn/dzkj/EN/
https://journal.xidian.edu.cn/dzkj/EN/Y2011/V24/I12/78
[1]伍小亭.供热计量中的几个问题[J].技术交流园地,2000,30(8):60-61.
[2]王树锋.供热计量仪表的前景[J].行业淘金,2006(10):17-18.
[3]徐伟,邹瑜.供暖系统温控与热量技术[M].北京:中国计划出版社,2000.
[4]程治国.供热分户智能控制系统[D].哈尔滨:哈尔滨理工大学,2003.
[5]黄贤武,郑筱霞.传感器原理与应用[D].北京:高等教育出版社,2004.
[6]李春树.网络热计量系统的研究与开发[D].兰州:兰州大学,2007.
Cited