摘要:

K型热电偶是工业生产中应用广泛的接触式测温元件。熟悉其工作原理,掌握和分析测温误差的来源及其不确定度的评定,能在一定程度上避免生产过程中造成的不必要损失,并提高温度测量的准确性。

关键词: 热电偶, 误差分析, 测温, 不确定度

Abstract:

K-type thermocouple is emerging in industrial production and the use of broad-contact temperature measurement devices.Familiar with the works,to grasp and analyze the sources of measurement error,and uncertainty assessment would appear unnecessary production losses can be avoided to a large extent,and to improve the accuracy of the temperature measurement.

Key words: thermocouple;error analysis;temperature measurement;uncertainty